DeutschEnglish

Type-tested electrical solution 1:

 

ENA3 Basic device:

 

Facts

- Release the anti-creep system at A3 fault

- Self-test of the complete device after every ride

- Monitoring of existing safety circuit device

- Monitoring of the magnetic switches (Door Zone)

- Monitoring of the bypass circuit door zone (if available)

- Monitoring the feedback switch

- For safety circuit voltage 24V – 230V AC / DC

 

Mounting

- DIN rail mounting in control box, alternatively with additional plastic housing

- 24VDC supply connection and involvement in safety circuit (2 taps)

- Installation and connection of the redundant solenoid switch using the supplied mounting kit (door zone monitoring)

- Attach two tapes per stop for the door zone

- Electrical connection of the respective brake actuator on our device (4 wire)

ENA3 + MSchalter u. Bänder.jpg